|
Long before the energy crisis, Paloma was pioneering a more
efficient tankless hot water system. Even though the energy
crisis has been somewhat quieted down, homeowners and businesses
alike are still interested in saving money and energy.
Haven't you ever experienced the inconvenience of a tanktype
water heater running out of hot water when you needed more?
Paloma can provide the luxury of continuous and instantaneous
hot water while saving on your gas bill. Wall mounted Paloma
tankless water heaters will save you twice the installation
space and a lot of time waiting for another tankful of water
to heat up while burning up energy and your hard earned money.
You'll enjoy a lifetime of hot water --- shower after shower
after shower.
Paloma offers the following models:
|
Model
No.
|
|
PH-6DP
|
PH-6DN
|
|
PH-12M-DP
|
PH-12M-DN
|
PH-24M-DP
|
PH-24M-DN
|
|
Type
of gas
|
|
L.P.
|
NAT.
|
|
L.P.
|
NAT.
|
L.P.
|
NAT.
|
|
Rated
input
(BTU/Hr.)
|
Full
|
43,800
|
43,800
|
Full
|
89,300
|
89,300
|
178,500
|
178,500
|
|
Half
|
|
Min.
|
30,000
|
30,000
|
37,700
|
37,700
|
|
Hot
water output
degree
rise
(U.S. gal/min.)
|
Burner
|
1 stage
|
Burner
|
PH-12M-D
|
PH-24M-D
|
|
Stage
Selection
|
Full
|
Min.
|
Full
|
Min.
|
Full
|
|
50ºF
rise
|
1.40
|
60ºF rise
|
0.79
|
|
0.87
|
|
|
70ºF
rise
|
1.00
|
70ºF rise
|
0.68
|
|
0.75
|
|
|
100ºF
rise
|
0.70
|
80ºF rise
|
0.59
|
|
0.65
|
|
|
90ºF rise
|
0.53
|
1.59
|
0.58
|
3.17
|
|
100ºF rise
|
0.48
|
1.43
|
0.52
|
2.85
|
|
Minimum
working
water
supply pressure
|
P.S.I.
|
4.3
|
P.S.I
|
Min.
|
2.1
|
2.4
|
|
Full
|
10.0
|
12.9
|
|
Height
x width x depth
|
Inch
|
29-5/8 x 10-1/4
x 9-7/8
|
Inch
|
35-3/4 x 13-3/4
x 11-3/4
|
40-3/4 x 18-3/4
x 14-7/8
|
|
Net
weight
|
LBS
|
20
|
LBS
|
36
|
76
|
|
Connection
|
Gas
|
1/2 NPT female
|
Gas
|
1/2 NPT female
|
3/4 NPT female
|
|
Water
hot (cold)
|
1/2 NPT male
|
Water hot (cold)
|
3/4 NPT male
|
3/4 NPT male
|
|
Flue
size
|
Inch
|
4 dia.
|
Inch
|
5 dia.
|
7 dia.
|
|
First
hour rating
|
Gallons
|
46
|
Gallons
|
105
|
215
|
|
Thermal
efficiency
|
%
|
80
|
%
|
81
|
80
|
|
Energy
factor
|
|
0.71
|
|
0.65
|
0.63
|
|
Pilot
gas consumption
|
BTU/Hr.
|
380
|
BTU/Hr.
|
380
|
380
|
|
Max.
water pressure
|
P.S.I.
|
150
|
P.S.I.
|
150
|
150
|
|
Min.
gas pressure
|
Inch
W.C.
|
10.0
|
3.9
|
Inch W.C.
|
11.1
|
4.7
|
11.0
|
4.7
|
|
Max.
gas pressure
|
Inch
W.C.
|
14.0
|
7.0
|
Inch W.C.
|
14.0
|
7.0
|
14.0
|
7.0
|
|
Water
pressure required: Optimum pressure, 40-60 psi.
Well water system, recommended 40-60 psi
with pressure tank.
|
|
Clearance:
The water heater shall be installed with the minimum
clearances to combustible material of 6 inches at the
sides, 2 inches at the rear and 16 inches above the
top of draft hood outlet. For alcove installation, the
water heater shall be installed above non-combustible
flooring. A minimum of 24 inches clearance from front
should be available for adequate inspection and servicing.
|
|